Beamline 4.0.2
Magnetic Spectroscopy and Scattering
- Endstation Vector Magnet
- Endstation Resonant X-Ray Scattering
- Endstation Superconducting Vector Magnet
- Endstation X-ray detected ferromagnetic resonance (XFMR)
Current status | Operational; open to general users |
---|---|
ALS-U Status | This beamline will temporarily close at the start of the ALS-U dark time and will resume operations after a commissioning period. For more information, see ALS-U Beamline Impacts and other ALS-U web pages. |
Source | EPU5 |
Minimum energy (eV) | 400 |
Maximum energy (eV) | 1,500 |
Research areas |
|
Technique category |
|
Flux/Brightness | 1 x 1013 photons/s/0.1%BW at 800 eV |
Resolving power | 5,000-10,000 |
Access modes |
|
Additional notes | Polarization is user selectable; linear polarization continuously variable from horizontal to vertical; left and right elliptical (or circular) polarization. |
Primary contact(s) | Christoph Klewe Alpha T. N’Diaye |
Beamline phone number | 510-495-2041 |
Endstation
Vector Magnet
Status | Operational; open to general users |
---|---|
Research areas |
|
Technique category |
|
Spot size | 100 μm x 100 μm |
Sample information | Solid samples |
Additional Notes | X-ray magnetic circular dichroism (XMCD); x-ray magnetic linear dichroism (XMLD); orbital polarization and interface studies. Magnetic fields up to 0.5 T in any direction; Sample temperature 15-750 K; electron yield, fluorescence yield, and luminescence yield detection, plus transmission mode |
Endstation
Resonant X-Ray Scattering
Status | Operational; open to general users |
---|---|
Research areas |
|
Technique category |
|
Spot size | 100 μm x 100 μm |
Sample information | Solid samples |
Additional Notes | Resonant soft x-ray diffraction (RSXD); x-ray resonant magnetic reflectometry (XRMR); resonant elastic x-ray scattering (REXS). Sample temperature 15-320 K; Detectors: Photodiode (7 decades) or CCD (16-bit); 2-theta: 0 - 160 deg, incidence: 0 - 180 deg; chi: 0 - 90 deg; Optional magnetic field: ~0.3 T out-of-plane OR ~0.1 T in-plane |
Endstation
Superconducting Vector Magnet
Status | Operational; open to general users |
---|---|
Research areas |
|
Technique category |
|
Spot size | 150 μm x 150 μm |
Sample information | Solid samples |
Additional Notes | Magnetic fields up to 3.8 T in any direction; Sample temperature 20-300 K; electron yield and luminescence yield detection |
Endstation
X-ray detected ferromagnetic resonance (XFMR)
Status | Operational; open to general users |
---|---|
Research areas |
|
Technique category |
|
Spot size | 100 μm x 100 μm |
Field of view/spatial resolution | 500 μm aperture |
Sample information | Thin films on luminescent substrates (e.g., Al2O3, MgO) |
Additional Notes | Coplanar RF waveguide 0.5–5 GHz; Magnetic field up to 0.5 T; Sample temperature 20–320 K; Luminescence yield detection; Transverse FMR, sensitive to phase of precession |